- ESP-SR #216: diagnosing repeated MultiNet command triggers
A Juejin analysis of ESP-SR issue #216 finds that the reported ESP32-S3 application loop dispatches a command whenever command_id[0] equals 1 without guarding the action with MultiNet’s per-frame detection state. It recommends recording frame state, result fields, and action IDs separately, and dispatching commands only when the current state is DETECTED and a valid candidate is present. The analysis did not reproduce the issue on a board or confirm an upstream fix, and it cannot establish whether MultiNet re-recognizes every frame or caches old result fields.